Rorke Data Galaxy 16i User Manual page 21

2gb/s fibre-to-sata raid subsystem scsi-to-sata raid subsystem
Table of Contents

Advertisement

Host Interfaces
Subsystem Model
Galaxy 16i GAL16IR-
U3DS
Galaxy 16i GAL16IR-
FC2S
Galaxy 16i GAL16IR-
FC2D
Table 1- 2: System Host Channels
SCSI-160 Host Ports:- The SCSI host connects to the Galaxy 16i
subsystem through two mini-SCSI connectors, which are located
at the back of the controller modules.
FC Host Ports:- The FC host connects to the Galaxy 16i
subsystem through two small form factor pluggable (SFP)
connector, which are located at the back of the controller
modules.
FC Speed Detection:- Speed auto-detection is specified by the FC
standard. If a 1Gbps port is connected to a 2Gbps port, it will
negotiate down and run at 1Gbps. If there are two 2Gbps ports on
either end of the link, the link will be run at 2Gbps.
Drive Interfaces
All the models come with sixteen SATA drive channels that are
connected to the back plane.
RCC Channels
The controllers in the redundant controller Galaxy 16i subsystem,
the Galaxy 16i GAL16IR-FC2D, each come with a single
Galaxy 16i User's Manual
Host Channels
2 x Ultra 160 SCSI
2 x 2Gbit/sec Fibre Channel
4 x 2Gbit/sec Fibre Channel
1-9