Burner and nozzle specifications

Table 1
Burner
Diameter
Rapid (R)
Semi Rapid (S)
Auxiliary (A)
Mini WOK (MW)
Supply pressures
*
At 15°C and 1013,25 mbar - dry gas
**
Propane
P.C.S. = 50.37 MJ/Kg
***
Butane
P.C.S. = 49.47 MJ/Kg
Natural
P.C.S. = 37.78 MJ/m
Model
Class
IP 640 S UK
II2H3+
7,30 (531 g/h - G30) (521 g/h - G31)
IP 641 S C UK
II2H3+ 7,80 (567 g/h - G30) (557 g/h - G31)
(1)
The values in g/h refer to the capacities with liquid gas (Butane, Propane).
S
R
S
A
IP 640 S UK
Thermal Power
(mm)
kW (p.c.s.*)
Nomin.
Reduc.
100
3.00
0.70
75
1.65
0.40
55
1.00
0.40
110
3.50
1.50
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
3
Gas section
(1)
Rated power (kW)
S
S
IP 641 S C UK
Liquid Gas
By-pass
Nozzle
Flow*
1/100
1/100
g/h
(mm)
(mm)
***
39
86
218
214
28
64
120
118
28
50
73
71
61
91
254
250
28-30
37
20
25
35
45
Electric section
Voltage and frequency
220-240V~ 50/60Hz
220-240V~ 50/60Hz
MW
A
Natural Gas
Nozzle
Flow*
1/100
l/h
**
(mm)
116(Y)
286
96(Z)
157
79(6)
95
138
333
20
17
25
Power (W)
0,6
0,6
GB