Burner And Nozzle Specifications - Indesit PAAI 642 IX/I WE Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Burner and nozzle specifications

GB
Table 1
TYPE OF GAS
USED
NATURAL GAS
(Methane)
G20
LIQUEFIED
PETROLEUM GAS
(Butane)
G30
LIQUEFIED
PETROLEUM GAS
(Propane)
G31
Type of gas used
G20 20 mbar
G30 28-30 mbar
G31 37 mbar
ELECTRIC SUPPLY: 220-240V~ 50/60Hz 0,6W
S
S
R
A
PAAI 642 IX/I WE
8
TYPE OF
NOZZLE
RATED
BURNER
THERMAL
FLOW RATE
Rapid
115Y
Semi-Rapid
95Z
Auxiliary
72X
Rapid
85
Semi-Rapid
63
50
Auxiliary
Rapid
85
Semi-Rapid
63
Auxiliary
50
Model configuration
4 BURNERS
1R - 2S -1A
1R - 2S -1A
1R - 2S -1A
RATED
CONSUMPTION
kW
3.00
286 l/h
1.65
157 l/h
1.00
95 l/h
218 g/h
3.00
120 g/h
1.65
1.00
73 g/h
3.00
214 g/h
1.65
118 g/h
1.00
71 g/h
Rated thermal
Total rated
ow rate (kW)
consumption
7.30
695 l/h
7.30
531 g/h
7.30
521 g/h
CATEGORY II2H3+
REDUCED
GAS PRESSURE
HEAT
mbar
CAPACITY
kW
min.
rat.
0.75
17
20
0.40
0.40
0.75
0.40
20
28-30
0.40
0.75
25
37
0.40
0.40
Air required (m³) for
burning 1 m³ of gas
9.52
30.94
23.80
max.
25
35
45

Advertisement