Burner and nozzle specifications

GB
Table 1
TYPE OF GAS
USED
NATURAL GAS
(Methane)
G20
LIQUEFIED
PETROLEUM GAS
(Butane)
G30
LIQUEFIED
PETROLEUM GAS
(Propane)
G31
Type of gas used
G20 20 mbar
G30 28-30 mbar
G31 37 mbar
ELECTRIC SUPPLY: 220-240V~ 50/60Hz 0,6W
S
S
R
A
PAA 642 /I(WH)
8
TYPE OF
NOZZLE
BURNER
THERMAL
FLOW RATE
Rapid
F2 118
Semi-Rapid
95Z
Auxiliary
72X
85
Rapid
63
Semi-Rapid
Auxiliary
50
Rapid
85
Semi-Rapid
63
Auxiliary
50
Model configuration
4 BURNERS
1R - 2S -1A
1R - 2S -1A
1R - 2S -1A
RATED
RATED
CONSUMPTION
kW
3.00
286 l/h
1.75
167 l/h
1.00
95 l/h
3.00
218 g/h
127 g/h
1.75
73 g/h
1.00
3.00
214 g/h
1.75
125 g/h
1.00
71 g/h
Rated thermal
consumption
ow rate (kW)
7.50
7.50
7.50
CATEGORY II2H3+
REDUCED
GAS PRESSURE
HEAT
CAPACITY
kW
min.
0.60
17
0.35
0.30
0.60
0.35
20
0.30
0.60
25
0.35
0.30
Total rated
Air required (m ) for
burning 1 m 3 of gas
715 l/h
9.52
545 g/h
30.94
535 g/h
23.80
mbar
rat.
max.
20
25
28
35
30
37
45
3