11-7 Damper
Function
The damper supplies the cold air from freezer room to chillroom by using the damper plate.
Chillroom gets colder when damper plate is open. When damper plate is close, chillroom
temperature will rise
How to
Measure
Blue
1
3 Yellow
Check the
Check the resistance between connectors 1,3 and 2,4.
It means that check electric current is flowing.
If there is resistance, damper is normal.
Standard
Damper
Red and Yellow
Red
2
White
3
,
2
4
Test Points
Result
373 ~ 456Ω
< Damper Circuit >
Check the
Test Points
Blue and White
- 64 -
Blue
1
White
3
Check the
,
1
3
< extension >
,
1
3
Result
373 ~ 456Ω