9-7 Poor cooling in Freezer compratment
No
1
Check the sensor resistance.
<CON7>
※ The sensor is determined by
the temperature.
For example, 23㏀ indicates -4°F.
2
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
3
Check if cold air blows from air vents with
your hand.
4
Check the air temperature.
Cold or not ?
Checking flow
Result & SVC Action
(1) To (2)
-22°F / -30°C
-13°F / -25°C
-4°F / -20°C
5°F / -15°C
14°F / -10°C
23°F / -5°C
32°F / 0°C
Status
Windy
No windy
Status
Cold
Not cold
- 51 -
Result
40 ㏀
30 ㏀
23 ㏀
17 ㏀
13 ㏀
10 ㏀
8 ㏀
SVC Action
Go to the 4
Check the F Fan motor
SVC Action
Explain to customer
Check the Compressor
And sealed system