Kenmore 795. 72063.11 series Service Manual page 38

Table of Contents

Advertisement

8-7 Defrost Heater Error (R dH)
No
1
Check the Door gasket.
2
Check the Defrost control part.
Defrost
Heater
3
Input Test 3 Mode.
(Push the button 3 times)
4
Check the Blue to Yellow.
<CON3>
5
Release the test mode.
push the button 1 times. (normal)
6
Check the Blue to Yellow.
<CON3>
Checking flow
Defrost
Sensor
Fuse-M
Result & SVC Action
Part
Fuse-M
34~42 Ω
Defrost
Heater
22 ㏀↑
Defrost
Sensor
Result
112 ~ 116 V
0 V
Result
0 V
112 ~ 116 V
- 38 -
Result
SVC Action
0 Ω
Go to the 3
Other
Change Fuse-M
Go to the 3
Change Fuse-M
Other
Go to the 3
Replace product
OFF
SVC Action
Go to the 5
Replace Main PCB
SVC Action
Explain to customer
Replace Main PCB

Advertisement

Table of Contents
loading

This manual is also suitable for:

795. 72062.21 series

Table of Contents