FAULT FINDING FLOW CHARTS

9.1

No Power

Is there
power to the
No
supply
outlet?
Yes
Is the power
cord fitted
No
correctly?
Yes
Is there
continuity of
the power
cord?
Yes
Is there
continuity of
the main
harness?
Yes
Fit new motor
control
module
58
Arrange repair of
supply etc. as
necessary
Refit correctly
Check as per
Section 6.1.1
(Electric) or 6.1.3
(Gas)
Check as per
Section 6.1.2
(Electric) or 6.1.4
(Gas)