Installation

Ventilation

Condensate can damage the coffee
machine or the housing unit.
The ventilation gaps given must be
observed.
Do not cover or block the ventilation
gaps.
Dust the ventilation gaps regularly.
Steam which is created when water is
heated up can condense on the interior
and the inside of the front of the coffee
machine.
When installing the coffee machine
ensure that there is sufficient ventilation
at the rear of the machine to allow
steam and heated air to escape without
hindrance.
The housing unit should be configured
as follows:
– Air intake  occurs via the plinth at
the bottom of the machine and the
air escapes at the top  at the rear
of the housing unit.
90
– A ventilation gap of at least 40 mm
depth must be allowed for behind the
machine for air to circulate.
– The ventilation cross-sections in the
plinth, housing unit and below the
room ceiling must amount to at least
2
200 cm
to ensure that air can
circulate without hindrance.
Top ventilation gap
The ventilation gap at the top of the
machine can be constructed in different
ways:
a directly above the coffee machine
with a ventilation grille (free air flow
of at least 200 cm
b in between the housing unit and the
ceiling
c through a suspended ceiling.
2
)