9.3.1.7.
Indoor Fan Motor Operation
A. Basic Rotation Speed (rpm)
• • • • Required rotation speed for fan is set to respond to the remote control setting (10 rpm unit)
[Cooling, Dry, Fan]
Remote Control
Tab (rpm)
PSHi
CS-ME10DTEG
900
CS-E15DTEW
1070
CS-E18DTEW
1110
[Heating]
Remote Control
Tab (rpm)
PSHi
CS-ME10DTEG
900
CS-E15DTEW
1080
CS-E18DTEW
1110
O
O
SHi
Hi
Me+
900
830
790
1070
1000
940
1110
1040
970
O
O
SHi
Hi
Me+
900
830
780
1080
1010
920
1110
1050
950
CS-ME7DKEG CS-ME10DD3EG / CS-ME10DTEG CS-E15DB4EW
O
O
O
Me
Me-
Lo
740
690
640
870
800
730
920
850
790
O
O
O
Me
Me-
Lo
730
680
630
830
730
630
860
770
680
65
Lo-
SLo
SSLo
590
530
370
680
630
370
740
630
370
Lo-
SLo
SSLo
590
530
370
590
530
300
630
540
370