Panasonic CS-ME7DKEG Service Manual page 62

Hide thumbs Also See for CS-ME7DKEG:
Table of Contents

Advertisement

CS-ME7DKEG CS-ME10DD3EG / CS-ME10DTEG CS-E15DB4EW
9.3.1.2.
Simultaneous Operation Control
1. Operation modes which can be selected using the
remote control unit:
Automatic, Cooling, Dry, Heating, Fan operation mode.
2. Types of operations modes which can be performed
simultaneously
• • • • Cooling operation and cooling, Dry or fan operation
• • • • Heating operation and heating operation
3. Types of operation modes which cannot be performed
simultaneously
• • • • While a cooling operation is in progress, a heating
operation cannot be performed by an indoor unit in
another room.
In the room where the operation button for cooling was
pressed first, the operation is continued. In the room
where the operation button for heating was pressed
afterward, the operation lamp of the indoor unit blinks,
where the attempt is made to establish the heating
operation. Its fan is stopped, and the air does not
discharged.
• • • • While a heating operation is in progress, a cooling
operation cannot be performed by an indoor unit in
another room.
In the room where the operation button for heating was
pressed first, the operation is continued. In the room
where the operation button for cooling was pressed
afterward, the operation lamp of the indoor unit blinks,
where the attempt is made to establish the cooling
operation. Its fan is stopped, and the air does not
discharged.
4. Operation mode priority control
• • • • The operation mode designated first by the indoor unit
has priority.
• • • • If the priority indoor unit stops operation or initiates the
fan operation, the priority is transferred to other indoor
units.
62

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents