Panasonic CS-ME7DKEG Service Manual page 45

Hide thumbs Also See for CS-ME7DKEG:
Table of Contents

Advertisement

2. Heating
Note:
a. UP:
• • • • If move from Lo, the fan speed will be shifted to Maximum 1,520 rpm.
• • • • If move from Maximum, the fan speed no change.
• • • • In up zone, 10 rpm is added for every 10 seconds until Maximum 1,520 rpm.
b. DOWN:
• • • • The fan speed will be decreased one step every 10 seconds until Minimum 1,270 rpm.
c. Current Output Fixed:
• • • • Maintain at present fan speed.
d. Instantaneous Maximum:
• • • • Fan speed will be increased to maximum auto fan speed.
e. Temperature in ( ) is for Powerful Mode operation.
C. Fan Motor Control
1. Motor specification
High voltage PWM Motor
2. Feedback Control
a. Number-of -rotations feedback
Immediately after the fan started, rpm is checked and duty is added, and feedback control is performed. For high voltage
PWM motor. It is done once every 0.5 seconds.
b. Offset duty T max/min limit
High voltage PWM motor has maximum offset duty.
(Refer to indoor fan motor control basic rotation speed.)
3. Abnormal detection Control
Conditions:
a. Out of rhythm signal input
b. If feedback number of rotations exceeded 2,550 rpm or when less than 50 rpm.
Control: Fans stop.
Return: Restart after 5 seconds.
* It will not detect out of rhythm condition within 5 seconds for phase control motor (PWM motor is when duty = 0) after start.
A fan stops when condition (1) and (2) happen within 25.0 seconds after fan starting, and if this happens for continuously
7 times, it will not retry.
→ FM lock processing
4. Restart Prohibition Control
Restart is prohibited within 5 seconds for phase control motor (PWM motor is when duty = 0) after dan stop (except re-ON
the power supply)
CS-ME7DKEG CS-ME10DD3EG / CS-ME10DTEG CS-E15DB4EW