Zone Weighting

This configuration allows the installer to select the "size" of
each zone. Typically, living areas are assigned a larger
weight %, or importance factor, than bedrooms and smaller
areas. The Zone weight affects what heating and cooling
stages are used to condition the calling zones. If only one
zone is calling for conditioning and that zones has a low
weight, only low stage may be used. Example: if a zone
weighted a 30% is calling for conditioning, the system may
not run until more zones are calling.