Minimum CFM to run a modulating furnace. This will in-
crease the minimum operating capacity of the furnace. De-
fault value is the furnace air flow for the lowest heat capacity.
Maximum CFM (only appears with modulating furnaces)
Maximum CFM to run a modulating furnace. This will reduce
the operating capacity of the furnace. Default value is the
furnace air flow for the highest heat capacity.

Dehum Drain

Turns off the continuous fan at the end of cooling cycle for five
minutes in order to drain the indoor coil of water. The fan will only
be turned off if a dehumidify demand existed at the start of or during
the cooling cycle. Default is enabled.

Off Delay

Amount of time the blower will continue to run after heating
has shut off.
90 seconds
120 seconds (default)
150 seconds
180 seconds