Table 56. Symptom-to-FRU index (continued)
Problem
indicator
Component
Amber LED is on
Power supply
and blue LED is
and fan unit
on, and Overall
v Amber Needs
Storage
Attention LED
Subsystem
on.
Needs Attention
v Blue Service
LED is on
Action Allowed
LED on.
RAID controller
v Amber
Controller
Needs
Attention LED
is on.
v Blue
Controller
Service Action
Allowed LED
is on.
Interconnect-
battery unit
v Amber Needs
Attention LED
is on.
v Blue Service
Action Allowed
LED is on.
Possible cause
Power supply and fan unit
failure or power supply
failure
RAID controller offline
RAID controller failure
Interconnect-battery unit
failure
Possible solutions
Use DS Storage Manager client software to verify
the failure and replace the power supply and fan
unit.
If you have placed the controller offline, use the
DS Storage Manager client software to place it
online.
If one controller has been placed offline by the
other controller, contact IBM support. (This is the
case if you use the DS Storage Manager client
software to make repeated attempts to bring an
offline controller online, but the controller keeps
reverting back to an offline state.)
If the RAID controller Needs Attention LED is on
and the Service Action Allowed LED for that RAID
controller is lit, replace the RAID controller.
If the Service Action Allowed LED for the RAID
controller is not lit, perform additional diagnostics
to identify other component failures. Replace the
other failed components before replacing the
RAID controller.
Contact IBM Support.
Chapter 6. Hardware maintenance