20.3 The RX level is too high
When the RX-level is too high (some steps above the limit) it is often due to some component in
the signal path that has changed characteristics because of ageing.
The only thing you have to do is a new RSSI-calibration.
20.4 The RX level is too low
When the RX-level is too low (some steps under the limit) and the RX-quality is 0, it is often
due to some component in the signal path that has changed characteristics because of ageing.
It is advisable to do a new RSSI-calibration.
If it is a RX-quality problem or if the RSSI-calibration did not make it or if it is a big RX-level
fault, go to "Sensitivity (RX quality)"-fault.
4/00021-3/FEA 209 544/18 B
Trouble Shooting Guide, Advanced
86(121)