Chassis Dimension And Weight; Environment - Sun Microsystems StorEdge S1 Array Manual

Hide thumbs Also See for StorEdge S1 Array:
Table of Contents

Advertisement

Chassis Dimension and Weight

Height
Width
Depth (with front bezel)
Weight (without drives)
Weight (fully loaded)
Shipping Weight (product and
packing)

Environment

The Sun StorEdge S1 array is designed to meet the following requirements:
Environmental Specifications
Climate Control
Temperature (dry bulb)
Short term (96 consecutive hrs)
Temperature derating (max)
Relative humidity (non−
condensing)
Short term (96 consecutive hrs)
Altitude (based on drives)
Heat dissipation (maximum)
Sound power
Earthquake
Sun StorEdge S1 Array
Just the Facts
U.S.
1.73 in (1 rack unit— 1U)
17.16 in.
18.6 in.
13 lbs
19.4 lbs
20 lbs
Location
Operating
Storage
Transit
Operating
Non−operating
Operating
Operating
Storage
Transit
Operating
Non−operating
Operating
Storage
Transit
Operating
Operating
Idle
Location
Metric
4.4 cm
43.6 cm
47.2 cm
5.9 kg
8.8 kg
9.5 kg
Minimum to Maximum Range
5°C to 40°C (41°F to 104°F)
–25°C to 65°C (–13°F to 149°F)
–25°C to 65°C (–13°F to 149°F)
–5°C to 55°C (23°F to 131°F)
–40°C to 70°C (–40°F to 158°F)
3.3°C per 1000m (1.7°F per 1000 ft)
above sea level
5% to 85%
5% to 95%
5% to 95%
5% to 90%
5% to 95%
0m to 3,000m (0 ft to 10,000 ft)
above sea level
0m to 12,000m (0 ft to 40,000 ft)
above sea level
0m to 12,000m (0 ft to 40,000 ft)
above sea level
150 watts, 512 BTU per hour
6.0B, in accordance with ISO 9296
6.0B, in accordance with ISO 9296
NEBS requirements for earthquake
Zone 4
15
9/27/01