Troubleshooting; Test Mode - Saeco New Royal HD 8930 Service Manual

Hide thumbs Also See for New Royal HD 8930:
Table of Contents

Advertisement

NEW ROYAL
5.1.

Test mode

SX1
MENU
BUTTON
SX1
Select ground/pre-ground
SX2
Espresso
SX3
Coffee
SX4
Access to Special Menu
DX1
Clean cycle
DX2
Cappuccino
DX3
Latte macchiato
DX4
Entry to Stand-By
To enter Test Mode:
- Switch on the machine.
- Press the four function keys in the sequence indicated below (SX3, SX2, SX4, SX1) before the
initialization bar is completed.
TITLE
SX1
SX2
INFO1
INFO2
INFO5
INFO6
DX2
The sectors highlighted in yellow on the following screens represent the various loads that can be
activated by pressing the keys indicated in each sector.
This load is deactivated by pressing the same key once more.
The sectors highlighted in green provide information on the sensor status.
Other conditions in which a load can be automatically deactivated are:
- If a work cycle is defi ned and ends (e.g., coffee grinder or brewing unit).
- A time-out is reached (e.g.: 5 sec for the boiler test).
The symbols
mode.
Saeco International Group
SX2
SX3 SX4
OK
ESC
MAIN FUNCTION
SX3
INFO3
INFO4
INFO7
DX3
DX4
can be activated with keys SX4 and DX1 and are used to navigate the Test
Menu access (hold down)
OK
ESC
Scroll menu up
Scroll menu down
Entry into Test Mode results in a screen divided into
sections, as illustrated in the diagram below
Rev. 01

05 TROUBLESHOOTING

DX1
DX2
DX3 DX4
SECONDARY FUNCTION
01
Page
/ 07

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents