Relief Valve - Saeco New Royal HD 8930 Service Manual

Hide thumbs Also See for New Royal HD 8930:
Table of Contents

Advertisement

NEW ROYAL
04 OPERATING LOGIC
4.4.

Relief valve

Drain to drip tray
Needle
Drain
Functions:
Safety valve: functions as a safety valve by opening towards the drain in the event that the pressure rises above
16-19 bar
Filling the circuit: The solenoid valve opens (drain position) and the pump is activated, automatically refi lling the
circuit by expelling the air in the pipe
Unit discharge: before the unit descends it opens briefl y, discharging the pressure created to prevent spraying and
making the dregs drier
Co ee beverage: when a coffee beverage is selected, the pump is charged briefl y during the grinding process and
the valve assumes the drain position in order to fi ll the pipes with hot water.