Inspection Of Electronic Expansion Valve; Outdoor Unit Fan Motor Check Procedure - Mitsubishi Electric DXK09ZJ-S Technical Manual

Inverter wall mounted type residential air-conditioner
Table of Contents

Advertisement

(a) Inspection of electronic expansion valve
• Inspection of electronic expansion valve as a separate unit
Measuring point
Resistance when normal
(b) Outdoor unit fan motor check procedure
  
  
  
CNFAN
DC308~336V
2) Fan motor resistance check
Measuring point
⑥ − ④
③ − ④
6
5
4
3
2
1
FM
0
GND
DC15V
(−)
Resistance when normal
Outdoor PCB
DC several (4~7V)

-
-
'09•SRK-DB-087D
'11 • SRK-T-118
Measuring
Resistance when
point
normal
⑥ − ④
③ − ④
② − ④
① − ④

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dxk12zj-sDxk18zj-s

Table of Contents