Scope Of Delivery; Conventional Use; Maintenance; Technical Data - Schneider Airsystems A202002 Original Operating Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 23
GB
UNM Base / CPM Base
Table of contents - Part 1
1.1

Scope of delivery ......................

1.2

Conventional use ......................

1.3

Technical data ..........................

1.4
Components.............................
1.5

Maintenance.............................

1.6
Vessel inspections .....................
1.1 Scope of delivery
A202002 / A211002 / A212002 / A711002 /
A711003:
– Compressor with instruction manual
A213002 / A214002 / A712002 / A712012 /
A713002 / A714002 / A715002 / A715102:
– Compressor with instruction manual
– Documents accompanying compressed air
vessel
1.2 Conventional use
The compressor is designed for generating
and storing compressed air only. Com-
pressed air is only suitable for compressed
air tools/devices/machines.
Any other type of use is considered contrary
to the intended use.
The compressor must not be used in poten-
tially explosive areas. Combustible, caustic
or toxic gases must not be sucked in!
1.3 Technical data
see Fig. 1a
1.4 Components
01
Compressor unit
02
Intake filter
03
Oil dipstick
04
Oil drain screw
06
Pressure pipe
07
Check valve
08
Vessel
09
Condensate drain valve
10
Pressure switch with ON/OFF switch
11
Safety valve
12
Pressure gauge (vessel pressure)
13
Pressure gauge (working pressure)
14
Electric motor
16
V-belt
17
Belt guard grating
18
Pressure reducer
19
Quick-action coupling
I/2
1.5 Maintenance
1.5.1
Cleaning the intake filter
2
1. Unscrew the intake filter. (Fig. 5a)
2
2. Clean the filter insert using the blow gun,
2
exchange the filter insert if necessary.
2
3. Screw the intake filter back on.
A711003:
2
1. Loosen the screws and open the housing
2
as shown in Fig. 5a.
2. Pull out the filter insert (Fig. 5a).
3. Clean the filter insert using the blow gun,
exchange the filter insert if necessary.
4. Insert the filter insert.
5. Close the housing and tighten the
screws.
1.6 Vessel inspections
A202002 / A211002 / A212002 / A711002 /
A711003:
No inspections are specified for the ves-
sels.
We recommend that a "qualified person" per-
form a pressure test on the vessel, depend-
ing on its rate of utilisation, after 10 years in
accordance with the Ordinance on Industrial
Safety and Health. Contact any of our service
partners.
 The statutory specified inspections must
be arranged in accordance with the appli-
cable regulations of the respective coun-
try in which the vessel is used.
A213002 / A214002 / A712002 / A712012 /
A713002 / A714002 / A715002 / A715102:
Compressor with type test: Inspection is
not required prior to commissioning.
Type identification: see compressor type
plate
We recommend that a "qualified person" per-
form a pressure test on the vessel, depend-
ing on its rate of utilisation, after 10 years in
accordance with the Ordinance on Industrial
Safety and Health. Contact any of our service
partners.
 It is essential to retain vessel documents
included in the delivery (= certification
documents) for the entire service life of
the vessel. The statutory specified inspec-
tions must be arranged in accordance
with the applicable regulations of the re-
spective country in which the vessel is
used.