Kinetic direct drive

Advertisement

TECHNICAL GUIDE
2) Direct drive indicator hand
Before installing the direct drive indicator hand, force the direct drive indicator hand position
back to " 0 " by resetting the built-in IC (system reset).
[How to retrieve the remaining power reserve (after system reset)]
* After system reset, power reserve indicator goes back to " 0 " but the energy is still stored in
rechargeable battery. Instead of using KINETIC energy supplier or manual charging, you can
retrieve the stored energy by following the operations below.
i) STEP 1
1. Pull out the crown to the second click position.
2. Hold it for two or more seconds.
3. Repeat the following action within two seconds; [push it back to the normal
position], [pull it out to the second click], [push it back to the normal positon],[pull
it out to the second click]and then [push it back to the normal position.]
4. The hand goes down below "0" shaking, then goes up again toward "D" (*note).
ii) STEP 2
1. Press the button at the 10 o'clock position.
2. Pull the crown out to the first click position then push it back to the normal
position immediately while holding down the 10 o'clock button.
3. After confirming that the hand moves up toward "M"(*note), release the 10
o'clock button. (The watch will continue working according to the duration time
indicated.)
*note: depending on the energy level = voltage stored
within two seconds