Error Code
Message Information
LCD Message
Details
Action
RFM2006
Message
Details
Action
SEC0031
Message
LCD Message
Details
Action
SEC0033
Message
LCD Message
Details
Action
SEL0006
Message
Details
Action
SEL0008
Message
Details
Action
SEL0012
Message
Internal Dual SD Module <name> failed. Check SD Card.
The SD card module is installed but improperly configured or
failed to initialize.
Reinstall the SD module and remove and reinstall SD cards.
Internal Dual SD Module <name> is write protected.
The module is write-protected. Changes may not be written
to the media.
If unintended, remove the media and disable write
protection.
The chassis is open while the power is on.
Intrusion detected. Check chassis cover.
The chassis is open. System performance may be degraded,
and security may be compromised.
Close the chassis. Check system logs.
The chassis is open while the power is off.
Intrusion detected. Check chassis cover.
The chassis was opened while the power was off. System
security may have been compromised.
Close the chassis and verify hardware inventory. Check
system logs.
All event logging is disabled.
This message is displayed when all event logging has been
disabled by the user.
If unintended, re-enable logging.
Log is full.
When the event log is full, additional events are not written
to the log. Older events may be overwritten and lost. This
message may also appear if the user disabled event logging.
Backup and clear log.
Could not create or initialize the system event log.