Dell PowerEdge R420xr Owner's Manual page 119

Hide thumbs Also See for PowerEdge R420xr:
Table of Contents

Advertisement

Error Code
Message Information
PCI1342
Message
Details
Action
PCI1348
Message
LCD Message
Details
Action
PCI1360
Message
LCD Message
Details
Action
PDR0001
Message
LCD Message
Details
Action
PDR1016
Message
LCD Message
Details
Action
A bus time-out was detected on a component at slot
<number>.
System performance may be degraded, or system may fail to
operate.
Cycle input power, update component drivers, if device is
removable, reinstall the device.
A PCI parity error was detected on a component at slot
<number>.
PCI parity error on slot <number>. Re-seat PCI card.
System performance may be degraded, or system may fail to
operate.
Cycle input power, update component drivers, if device is
removable, reinstall the device.
A bus fatal error was detected on a component at slot
<number>.
Bus fatal error on slot <number>. Re-seat PCI card.
System performance may be degraded, or system may fail to
operate.
Cycle input power, update component drivers, if device is
removable, reinstall the device.
Fault detected on drive <number>.
Fault detected on drive <number>. Check drive.
The controller detected a failure on the disk and has taken
the disk offline.
Remove and re-seat the failed disk. If the issue persists, see
Getting
Help.
Drive <number> is removed from disk drive bay <bay>.
Drive <number> removed from disk drive bay <bay>. Check
drive.
The controller detected that the drive was removed.
Verify drive installation. Re-seat the failed drive. If the issue
persists, see
Getting
Help.