Dell PowerEdge R420xr Owner's Manual page 118

Hide thumbs Also See for PowerEdge R420xr:
Table of Contents

Advertisement

Error Code
Message Information
MEM8000
Message
LCD Message
Details
Action
PCI1302
Message
Details
Action
PCI1304
Message
LCD Message
Action
PCI1308
Message
LCD Message
Details
Action
PCI1320
Message
LCD Message
Details
Action
118
Correctable memory error logging disabled for a memory
device at location <location>.
SBE log disabled on <location>. Re-seat memory.
Errors are being corrected but no longer logged.
Review system logs for memory exceptions. Reinstall
memory at location <location>.
A bus time-out was detected on a component at bus <bus>
device<device> function <func>.
System performance may be degraded. The device has failed
to respond to a transaction.
Cycle input power, update component drivers, if device is
removable, reinstall the device.
An I/O channel check error was detected.
I/O channel check error detected. Power cycle system.
Cycle input power, update component drivers, if device is
removable, reinstall the device.
A PCI parity error was detected on a component at bus
<bus>device<device>function <func>.
PCI parity error on bus <bus> device <device> function
<func>. Power cycle system.
System performance may be degraded, PCI device may fail
to operate, or system may fail to operate.
Cycle input power, update component drivers, if device is
removable, reinstall the device.
A bus fatal error was detected on a component at bus
<bus>device<device>function <func>.
Bus fatal error on bus <bus> device <device> function
<func>. Power cycle system.
System performance may be degraded, or system may fail to
operate.
Cycle input power, update component drivers, if device is
removable, reinstall the device.