Output Definitions - ADEMCO VISTA-20P series Programming Manual

Hide thumbs Also See for VISTA-20P series:
Table of Contents

Advertisement

80 OUTPUT DEFINITIONS

Fill in the required data on the worksheet below and follow the programming procedure in the installation manual as you
enter the data during the displays and prompts that appear in sequence.
Notes: 1. For Relays, 4229 and 4204 devices are programmed in *79, *80, and *81 modes.
2. For Powerline Carrier devices (plcd), field
3. Tampers of expansion units cannot be used to operate devices.
Output
Function
Activated by
Number
0=delete
(V20P=1-48)
1=zn list
(V15P=1-24)
2=zn type
3=zn no.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
ZONE TYPE/SYSTEM OPERATION – Choices for Zone Types are:
00 = Not Used
01 = Entry/Exit#1
02 = Entry/Exit#2
03 = Perimeter
04 = Interior Follower
Choices for System Operation are:
20 = Arming–Stay
21 = Arming–Away
22 = Disarming (Code + OFF)
31 = End of Exit Time
32 = Start of Entry Time
33 = Any Burglary Alarm
36 = **At Bell Timeout***
www.PDF-Zoo.com
Activation Type and Detail
Zone List
Zone Type
Zone No.
(ZL)
(ZT)
(ZN)
1-8 = list
(see table
00=none
below)
01-64
05 = Trouble Day/Alarm Night
10 = Interior w/Delay
06 = 24 Hr Silent
12 = Monitor Zone
07 = 24 Hr Audible
14 = Carbon Monoxide
08 = 24 Hr Aux
16 = Fire w/Verification
09 = Fire
23 = No Alarm Response
38 = Chime
39 = Any Fire Alarm
40 = Bypassing
41 = **AC Power Failure
42 = **System Battery Low
43 = Communication Failure
27 must be programmed with a House Code.
Partition
Event (for zone list/activated by)
Number
By Zone List
(P)
(if using ZT trig)
0 = restore
0 = restore
0 = any
1 = alarm
1 = alrm/flt/trbl
1 = partition 1
2 = fault
2 = partition 2
3 = trouble
3 = common
24 = Silent Burglary
77 = Keyswitch
81 = AAV Monitor Zone
90-91 = Configurable
52 = Kissoff
54 = Fire Zone Reset
58 = Duress
60 = AAV Trigger
66 = Function key†
67 = Bell Failure
68 = TELCO Line Fault
78 = Keyswitch red LED†††
79 = Keyswitch green LED†††
– 11 –
Action
0 = off
By Zone No.
1 = close 2 secs
2 = stay closed
V20P=1-18
3 = pulse
4 = toggle
V15P=1-8,
5 = duration 1
††
6 = duration 2
††
Note: In normal operation mode:
Code + # + 7 + NN Key Entry starts Device
Code + # + 8 + NN Key Entry stops Device
** Use 0 (any) for Partition No. (P) entry.
*** Or at Disarming, whichever occurs earlier.
† Use *57 Menu mode to assign the function key.
†† Duration is set in program field *177.
††† Device action not used for these choices.
Output
Device
Number
Type
R = relay
T = trigger
X = X10
17, 18

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vista-20ps seriesVista-15p series

Table of Contents