7. Possible Malfunctions

PROBLEM
The unit is turned on
but the control light
(brewing indicator) has
not come on.
Coffee machine is
turned on but does not
function.
The coffee machine
shuts off.
The unit is turned on,
the brewing indicator is
on, but hot water is not
flowing out.
The unit is turned on, the
brewing indicator does
not come on and hot
water does not flow out.
When turned on a fuse
immediately burns out.
The above problems only serve for orientation and as examples. Should these or
similar problems occur, turn the device off immediately and discontinue using it.
For having the device checked and repaired, contact qualified service personnel
or the dealer immediately.
CAUSE
Plug not connected
correctly
Fuse of mains opened
Control lamp defect
Switch defect
Coffee machine is
overdue a
decalcification
Overheating protection
was triggered.
Thermostat defect
Heating element defect
Thermostat defect
Control panel is
damaged
Damaged filling switch
Short-circuit
REMEDY
Connect plug correctly
Control fuse, test
machine on other plug
Contact supplier
Contact supplier
Pull plug and let coffee
machine cool off, press
RESET-button on the
back of the machine.
Decalcify machine.
Pull plug and let the
coffee machine cool
off. Press the RESET
button on the back of
the machine.
Contact supplier
Contact supplier
Contact supplier
Contact supplier
Contact supplier
Contact supplier
- 31 -