Troubleshooting; Specifications - Honeywell RLV4300 Owner's Manual

Hide thumbs Also See for RLV4300:
Table of Contents

Advertisement

Available languages

Available languages

Troubleshooting

Problem
Thermostat's
housing is hot.
Wrong temperature
is displayed.
Wrong time is
displayed.
Temperature
does not change
according to the
programmed
schedule.
LP appears on the
screen or the screen
is blank despite
there is no power
outage.

Specifications

Supply: 120/240 VAC, 60 Hz
Minimum load:
Maximum load: 12.5 A (resistive only)
Display range: 0 °C to 50.0 °C (32 °F to 99 °F)
Setpoint range: 5.0 °C to 27.0 °C (41 °F to 81 °F)
Resolution: 0.5 °C (1 °F)
Storage temperature: -20.0 °C to 50.0 °C (-4 °F to 120 °F)
Solution(s)
This condition is normal. Ensure that the heater capacity does not exceed the
thermostat's maximum load.
Correct it if any of the following situations exists:
• The thermostat is exposed to an air draft.
• The sticker on the thermostat's screen has not been removed.
• The thermostat is located near or above a heat source such as a light dimmer
The time is not yet set or the thermostat was without power for more than 5
hours.
• Ensure the thermostat is in Automatic mode.
• Check the clock and the schedule. If the thermostat is configured for
12-hour format, ensure that PM appears on the screen when afternoon times
are displayed.
The thermal circuit breaker in the heater is opened. This can happen if the
heater is obstructed by furniture or curtain and has overheated, or if the
thermal circuit breaker is defective or too sensitive.
1.25 A (resistive only)
150 W @ 120 V AC
300 W @ 240 V AC
1500 W @ 140 V AC
3000 W @ 240 V AC
9