15.10
Filter Check Control
•
This control detects the contamination of filter from the accumulated operation time of indoor unit
Model
Wall mounted
Except above
•
Accumulated time will be multiplied by a correction factor
Fan Number Group
Below Lo
Below Me
Except above
•
To inform user to clean the filter, FILTER RESET display on the wired remote control LCD and FILTER LED on
indoor unit remote control receiver / indicator will blink for 10 seconds each time operation ON and operation
OFF.
ON
Indoor
operation
OFF
Filter LED/Filter
RESET LCD
Filter check time (hour)
360
1000
Correction factor (%)
50
75
100
Blink
10s
10s
99
Blink