Compressor Discharge Temperature Control

This control will operate if compressor discharge temperature is detected hot at alert level.
If Compressor Discharge Temperature 100°C, liquid bypass valve will open.
o
If Compressor Discharge Temp 105°C, compressor frequency will reduce 10% if the compressor discharge
o
temp still at down zone.
The compressor frequency will only reduce max 2 times with 3 minutes interval OR to minimum frequency.
If compressor already reduced to minimum level but temp still at down zone, gas bypass valve will opens.
14.6

Condenser Temperature Control

During Heating operation only, this control will start if below conditions are fulfilled:
Total capacity of thermostat ON indoor units maintain for 10 minutes
o
None of the indoor units' heat exchanger > 40°C
o
Every interval of 60 sec, compressor frequency will increase 20% if the indoor heat exchanger temperature still in
up zone.
The compressor frequency will only increase maximum 5 times OR up to maximum frequency
This control will be ignored if any of the following control activated:
Deice
o
Low Load
o
Overload
o
Compressor Discharge Temperature Control
o
Total Current Protection
o
Night Time Low Noise Control
o
14.7

Compressor Restart Delay Control

Compressor only can be startup after at least 3 minutes of compressor OFF.
During this control, compressor cannot restart and gas bypass valve is ON.
14.8

Outdoor Residual Heat Removal Control

When compressor OFF, outdoor fan operate for 1 minute to remove the remaining heat.
14.9

Compressor Stops Control

This control ensures compressor is stopped within 30 seconds during normal operation.
If compressor stop is due to protection control, compressor will stop immediately.
Outdoor fan motor will continue to run at maximum speed for 60 seconds after compressor OFF signal is
received.
Gas bypass valve will ON for 3 minutes once received compressor OFF signal.
Liquid Bypass Valve Control
Liquid Bypass Valve Control
Open
Open
Close
Close
Unchanged
Unchanged
(ON)
(ON)
(OFF)
(OFF)
zone
zone
o
o
o
o
80
80
C
C
100
100
C
C
Up
Up
zone
zone
Normal Control
Comp Stop Signal
Comp Frequency Control
Comp Frequency Control
Unchanged
Unchanged
Free
Free
zone
zone
Zone
Zone
o
o
90
90
C
C
Unchanged
Unchanged
Free
Free
zone
zone
zone
zone
o
o
o
o
40
40
C
C
45
45
C
C
Max 30sec
Time (Sec)
86
Comp
Comp
Down Zone
Down Zone
Stop
Stop
o
o
o
o
105
105
C
C
110
110
C
C

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents