Classic Flow Mode Settings
Controller Configuration
Opening the Function Menu and Making Settings
E 2010 Nordson Corporation
To use Classic Flow mode, the controller must be configured for it. Refer to
Controller Configuration on page 3-17.
In Classic Flow mode, flow air and atomizing air ranges are:
Flow air from 0--5.95 M
S
Atomizing air from 0--5.95 M
S
To set flow or atomizing air:
1. Press the Flow or Atomizing button. The LED on the selected button
lights.
2. Turn the knob to increase or decrease the setpoints. The setpoints are
automatically saved if they do not change for 3 seconds, or when any
button is pressed.
Figure 3-19 Classic Mode -- Flow Air or Atomizing Air Setpoints
When the spray gun is not triggered the setpoints are displayed.
S
When the spray gun is triggered the actual flows are displayed.
S
Press and hold the Nordson button for 5 seconds. The
Function/Help display lights to show the Function numbers and values. Use
the Functions to configure the controller for your application.
The Function numbers are in the form F00--00 (Function number--value).
To scroll through the function numbers rotate the knob. To select the
displayed function number, press the Enter button.
When the function is selected the function value blinks. To change the
function value, rotate the knob. Press the Enter button to save the change
and exit the value, so that rotating the knob now scrolls through the function
numbers.
3
/HR (0--3.5 SCFM in 0.05 increments).
3
/HR (0--3.5 SCFM in 0.05 increments).
Flow
Atomizing
3-17
Operation
Part 1102771A