5.2 Monitor operational status

(1) Functions
● Displays the operational status of the IJ printer.
● Saves the Ink operating time and Print count once an hour (1 minute each hour).
When there was a power failure, returns to the previously saved state.
● The following items are also displayed in the Print description screen (initial menu).
(Items displayed in Print description screen: Ink operating time, Cumulative op. time, Print count, Ink pressure.)
Item
Ink operating time
(variable value)
Ink alarm time
Cumulative op. time
Print count
(variable value)
Ink name
Makeup name
Ink viscosity
Ink pressure
Ambient temperature
Deflection voltage
Excitation V-ref.
Excitation frequency
(2) Operation
Press Operation management in the Maintenance menu.
1
Operation management
Ink operating time
Ink alarm time
Cumulative op. time
Print count
Ink, makeup
Ink viscosity
Ink pressure
Ambient temperature
Deflection voltage
Excitation V-ref.
Excitation frequency
5-3 ●Monitor operational status
●Displays the operating time from the last ink replacement.
●At ink replacement, set to "0". Displays up to 9,999 hours.
●When the Ink alarm time is exceeded, displays an ink replacement alarm message.
●Displays the time which becomes the ink replacement standard.
●Always displays the standard value.
●Displays the cumulative operating time. The value cannot be changed.
●Displays up to 999,999 hours.
●Displays the number of printings.
●A value of 0 to 999,999,999 can be set.
●Displays the type of ink used.
●Displays the type of makeup used.
●Displays the ink viscosity
●Standard value is 100.
●Displays the ink pressure.
●The standard value is always displayed.
●Displays the ambient temperature and allowable ambient temperature.
●Displays the deflection voltage in the Ready state.
●Displays the set excitation V-ref. value.
●Displays the nozzle excitation frequency.
[Ready   ]
0000
(hours)
1200
(hours; standard value: 1200)
000000
(hours)
000000000
(prints)
JP-K69, TH-TYPE A
100 (standard value:100)
0.250 (MPa; standard value: 0.250)
20 (℃; range: 0∼45)
5. 7 (kV)
11 (0∼19)
75. 4 (kHz)
Description
2015.07.07 12:45
Com=0