basement is 50psi (345kpa) it will be about 40psi (276kpa) on the
second floor or a reduction of about 5psi (34kpa) for every 10 feet of
elevation.
Location:
The location of the Water Softener should be selected on the basis of
the following factors. If at all possible, piping normally requiring
unconditioned water should be bypasses. This many not be practical,
however is all cases.
Temperature:
The Water Softener should be installed in an area protected from
extreme heat. Do not allow Water Softener to freeze. Also, the
Water Softener must not be located directly adjacent to a furnace or
water heater or in an area where it may be exposed to direct sunlight.
An outdoor location is not recommended unless the Water Softener is
protected from rain, blowing sand or dust and extreme cold or heat.
Caution:
If the Water Softener is installed on the water line, hot water may
back up into the Water Softener and damage the Water Softener.
Install a check valve after the Water Softener. For additional
protection, install a "Y" strainer to prevent Water Softener media from
entering the Water Softener service line.
Electrical Requirements and Power Consumption;
The Water Softener should be located near an electrical outlet,
preferably a designated electrical outlet. The Water Softener control
valve c/w a 15 foot power cord.