Troubleshooting

There are 26 ways to improperly connect two packs to a charger! After the START/STOP button is
pressed, a special battery checking sequence automatically checks every wire before initiating a charge.
It is possible to get an unrelated safety code from a simple wiring issue.
Operating errors appear as messages in the display. To determine the problem, look up the description
below. Correct the error. If errors continue, contact Hobby King Customer Service.
Code/Message
Neg. Term. < 0V
Supply < 10 Volts
Supply > 32 Volts
Supply Unstable
Ch2 No Add Up
Chg. Overvoltage
C2 Pack Detected
Series Chargers
Low Voltage Cell
Cell < 0.1V
Reverse Polarity
Node 10 < 0V
Ch2 Bad S. Count
System Softstart
2 Pack Con. Err.
Ch1 No Add Up
Unbalanced Only
Ch1 has no pack
Positive < 0V
Butt Not Pressed
Pack Detect CH1
Pack Detect CH2
Charge Timeout
Bad Amps Setting
Amps Not Raising
Bad Fuel Table #
Bad Lith Fuel Tb
A123 < 2.7V/CELL
A123 > 3.8V/CELL
Options Corrupt
L.Supply V.Limit
No Auto Amps
Chem Not Found
LIPO < 3.0V/CELL
LIPO > 4.2V/CELL
Set Amps >= 2A
Bad Banana Tot V
Preset is Blank
No Fuel Table
January 17, 2012 ver 1.0 www.revolectrix.com
Problem
Check pack wiring
Input supply voltage is too low
Input supply voltage is too high
Check for a loose supply connection or thin wiring
Check pack wiring or dirty connectors
Cell is too high
A pack was detected on channel 2 after starting charge
Check Pack wiring. Check for 2 chargers on a series pack.
A cell is too low
The cell voltage is too low on a cell
Check pack wiring
Check pack wiring
Channel 2 couldn't identify the pack. Check for correct node setting.
Check the power supply is big enough. Loose input connections.
Check pack wiring
Check pack wiring or dirty connectors
Unbalanced charge detected voltage on the node connector.
Check pack wiring or dirty connectors
Check bananas
The confirm chemistry mode button was not pressed
Unbalanced charge detected voltage on the node connector
Unbalanced charge detected voltage on the node connector
The pack is taking too long to charge
Charger safety check
Check the banana wiring
Corrupted preset. Factory restore the charger
Corrupted preset. Factory restore the charger
Cell low voltage
Cell high voltage
Factory restore the charger
The supply voltage reached the cutoff
Auto amps are not allowed in some chemistries
Corrupted preset. Factory restore the charger
Cell low voltage
Cell high voltage
Lower the amps setting
Check the connectors. Clean the connectors.
Change presets or factory restore
Corrupted preset. Factory restore the charger