Daikin outdoor units are neat and sturdy and can be mounted easily
on a roof or terrace or simply placed against an outside wall.
1
1
1
• Outdoor Units • R-410A • RYN-E3V1B
• Split Sky Air • Outdoor Units
Outdoor units are fitted with a swing compressor, renowned for its low
noise and high energy efficiency

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RYN-E3V1B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Daikin RYN-E3V1B

  • Page 1 Outdoor units are fitted with a swing compressor, renowned for its low noise and high energy efficiency • Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply placed against an outside wall. • Split Sky Air • Outdoor Units...
  • Page 2: Technical Specifications

    • Outdoor Units • R-410A • RYN-E3V1B Specifications NOMINAL CAPACITY AND NOMINAL INPUT RYN50E3V1B RYN60E3V1B Indoor Units FTYN50EV1B FTYN60EV1B combination indoor units + outdoor units Cooling Standard capacity Heating Standard capacity Nominal input Cooling Standard 1.55 1.99 Heating Standard 1.60 2.04...
  • Page 3: Electrical Specifications

    • Outdoor Units • R-410A • RYN-E3V1B Specifications TECHNICAL SPECIFICATIONS RYN50E3V1B RYN60E3V1B Compressor Quantity Motor Model 2YC36BXD#A Type Hermetically sealed swing compressor Motor 1100 1100 Output °CDB Operation Cooling -10.0 -10.0 Range °CDB 46.0 46.0 Heating °CWB °CWB Sound Level...
  • Page 4 • Outdoor Units • R-410A • RYN-E3V1B Specifications ELECTRICAL SPECIFICATIONS RYN50E3V1B RYN60E3V1B Wiring For Power Quantity connections Supply For connection Quantity with indoor Remark Including earth wiring Power Supply Intake Outdoor unit only • Split Sky Air • Outdoor Units...
  • Page 5 • Outdoor Units • R-410A • RYN-E3V1B Features • Split Sky Air • Outdoor Units...
  • Page 6: Cooling/Heating Capacity Tables

    • Outdoor Units • R-410A • RYN-E3V1B Capacity tables 4 - 1 Cooling/Heating capacity tables FTYN50F+RYN50E 14.7 Cooling 50Hz 220-240V 0.28 I n door Outdoor temperature (°CDB) (°C) (°C) Heating 50Hz 220-240V 16.1 I n door Outdoor temperature (°CWB) (°C)
  • Page 7 • Outdoor Units • R-410A • RYN-E3V1B Capacity tables 4 - 1 Cooling/Heating capacity tables FTYN50FV1B+RYN50E3V1B 14.7 Cooling 50Hz 220-240V 0.28 I n door Outdoor temperature (°CDB) (°C) (°C) Heating 50Hz 220-240V 16.1 I n door Outdoor temperature (°CWB) (°C)
  • Page 8 • Outdoor Units • R-410A • RYN-E3V1B Capacity tables 4 - 1 Cooling/Heating capacity tables FTYN60FV1B+RYN60E3V1B 16.2 Cooling 50Hz 220-240V 0.29 I n door Outdoor temperature (°CDB) (°C) (°C) Heating 50Hz 220-240V 17.4 I n door Outdoor temperature (°CWB) (°C)
  • Page 9 • Outdoor Units • R-410A • RYN-E3V1B Capacity tables 4 - 1 Cooling/Heating capacity tables FTYN60F+RYN60E 16.2 Cooling 50Hz 220-240V 0.29 I n door Outdoor temperature (°CDB) (°C) (°C) Heating 50Hz 220-240V 17.4 I n door Outdoor temperature (°CWB) (°C)
  • Page 10: Dimensional Drawing & Centre Of Gravity

    • Outdoor Units • R-410A • RYN-E3V1B Dimensional drawing & centre of gravity 5 - 1 Dimensional drawing unit (mm) RYN50-60 E Drain outlet Wall height on air outlet side = Minimum space for air passage (I.D. J 15.9 hose for connection)
  • Page 11: Centre Of Gravity

    • Outdoor Units • R-410A • RYN-E3V1B Dimensional drawing & centre of gravity 5 - 2 Centre of gravity RYN50-60E The position of foundation bolt 4D051638C • Split Sky Air • Outdoor Units...
  • Page 12: Piping Diagram

    • Outdoor Units • R-410A • RYN-E3V1B Piping diagram RYN50-60E Outdoor unit Heat exchanger Outdoor temperature thermistor Capillary tube 1 Muffler with Refrigerant flow filter Capillary tube 2 Cooling Capillary tube 3 Heating Heat exchanger thermistor Capillary tube 4 Motor operated...
  • Page 13: Sound Data

    • Outdoor Units • R-410A • RYN-E3V1B Sound data 7 - 1 Sound pressure spectrum RYN50E (Cooling) RYN50E (Heating) approximate approximate threshold hearing threshold hearing for for continuous noise continuous noise 3D051717B 3D051717B Octave band center frequency (Hz) Octave band center frequency (Hz)
  • Page 14: Operation Range

    • Outdoor Units • R-410A • RYN-E3V1B Operation range RYN50-60E Cooling Heating (-15 °CDB) Indoor temp. (°CWB) Indoor temp. (°CDB) Notes: The graphs are based on the following conditions: + Equivalent piping length 7.5 m + Level difference + Air flow rate...
  • Page 15 • Outdoor Units • R-410A • RYN-E3V1B Operation range • Split Sky Air • Outdoor Units...