HIGH WATER TEMP
DOOR BLOCKED
COOLING WAIT +
ALARM
46
The circulation pump is
blocked.
Insuffi cient plant pressure.
Presence of air in the system.
The automatic cleaning of the
brazier results blocked.
Attempt to release the alarm
with boiler still in cooling mode
Check the hydraulic plant pressure.
Bleed the air from the plant.
Switch off the machine, wait for complete cooling and repeat
the ignition cycle.
If the problem persists, the restoration operations must be
carried out by an authorised technician.
Switch off the machine, wait for complete cooling and repeat
the ignition cycle.
If the problem persists, the restoration operations must be
carried out by an authorised technician.
Every time the boiler displays one of the alarms listed above it
will switch-off automatically.
The boiler will block any alarm release attempt during
this phase, showing the alarm itself and WAIT FOR COOL.
alternately on the display.
The alarm can only be released using button 1 when it switch-
off has been completed.