20. BALANCE Gain Data

Function
The external control equipment changes the BALANCE gain data of the plasma
monitor.
Transmission Data
DFH 80H
60H
7FH
03H
DATA00: USER PICTURE Gain Flag
DATA01: BALANCE Gain Flag
DATA02: BALANCE Gain
ACK
7FH
60H
80H
7FH
02H
DATA00: USER PICTURE Gain Flag
DATA01: BALANCE Gain Flag

21. SCREEN MODE Select

Function
The external control equipment switches the screen mode of the plasma monitor.
Transmission Data
DFH 80H
60H
51H
01H
DATA00: 02H: STADIUM
03H: ZOOM
04H: NORMAL
05H: FULL
06H: TRUE (REAL)
ACK
7FH
60H
80H
51H
01H
DATA00: 02H: STADIUM
03H: ZOOM
04H: NORMAL
05H: FULL
06H: TRUE (REAL)

22. V. POSITION Gain Data

Function
The external control equipment changes the V. POSITION gain data of the
plasma monitor.
Transmission Data
DFH 80H
60H
7FH
03H
DATA00: USER PICTURE Gain Flag
DATA01: V. POSITION Gain Flag
DATA02: V. POSITION Gain
ACK
7FH
60H
80H
7FH
02H
DATA00: USER PICTURE Gain Flag
DATA01: V. POSITION Gain Flag
DATA00 DATA01 DATA02 CKS
05H
02H
EAH: -22
FFH: -01
00H: 0
01H: +01
16H: +22
DATA00 DATA01 CKS
05H
02H
DATA00 CKS
DATA00 CKS
DATA00 DATA01 DATA02 CKS
03H
01H
C0H: -64
FFH: -01
00H: 0
01H: +01
40H: +64
DATA00 DATA01 CKS
03H
01H

23. H. POSITION Gain Data

Function
The external control equipment changes the H. POSITION gain data of the
plasma monitor.
Transmission Data
DFH 80H
60H
7FH
DATA00: USER PICTURE Gain Flag
DATA01: H. POSITION Gain Flag
DATA02: H. POSITION Gain
ACK
7FH
60H
80H
7FH
DATA00: USER PICTURE Gain Flag
DATA01: H. POSITION Gain Flag

24. V-HEIGHT Gain Data

Function
The external control equipment changes the V-HEIGHT gain data of the plasma
monitor.
Transmission Data
DFH 80H
60H
7FH
DATA00: USER PICTURE Gain Flag
DATA01: V-HEIGHT Gain Flag
DATA02: V-HEIGHT Gain
ACK
7FH
60H
80H
7FH
DATA00: USER PICTURE Gain Flag
DATA01: V-HEIGHT Gain Flag

25. H-WIDTH Gain Data

Function
The external control equipment changes the H-WIDTH gain data of the plasma
monitor.
Transmission Data
DFH 80H
60H
7FH
DATA00: USER PICTURE Gain Flag
DATA01: H-WIDTH Gain Flag
DATA02: H-WIDTH Gain
ACK
7FH
60H
80H
7FH
DATA00: USER PICTURE Gain Flag
DATA01: H-WIDTH Gain Flag
46
03H
DATA00 DATA01 DATA02 CKS
03H
02H
80H: -128
FFH: -01
00H: 0
01H: +01
7FH: +127
02H
DATA00 DATA01 CKS
03H
02H
03H
DATA00 DATA01 DATA02 CKS
03H
07H
00H: 0
40H: +64
02H
DATA00 DATA01 CKS
03H
07H
03H
DATA00 DATA01 DATA02 CKS
03H
08H
00H: 0
40H: +64
02H
DATA00 DATA01 CKS
03H
08H

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plasmasync 50xm2aPlasmasync px-50mp2Px-50xm2a

Table of Contents