4-9. Remote 14 Receptacle RC3 Information (Models With CV Option)

A
J
K
K
I
I
B
B
C L N
M
M
D
D
G
G
F
E
*The remaining sockets are not used.

4-10. Terminal Strip 2T Connections (Models With CV Option)

2
H
OR
OR
Ref. ST-800 862-B
Ref. ST-800 862-B
1
Socket*
A
24 volts ac. Protected by circuit
breaker CB4.
B
Contact closure to A completes 24
volts ac contactor control circuit.
I
115 volts ac. Protected by circuit
breaker CB3.
J
Contact closure to I completes 115
volts ac contactor control circuit.
G
Circuit common for 24 and 115
volts ac circuits.
C
0 to +10 volts dc output to remote
control from min to max of Amper-
age/Voltage control R1.
A/V
A/V
A/V
D
Remote control circuit common.
E
0 to +10 volts dc input command
signal from remote control.
K
Chassis common.
Y Stop engine.
If remote control plug does not fit in
receptacle RC3, wire cord directly
to terminal strip 2T.
Y Do not connect to Remote 14
receptacle RC3 and terminal
strip 2T at the same time. Use
only one remote control
method.
Open right side door.
1
Cover
2
Terminal Strip 2T
Connect leads to 2T using terminal
information shown in Section 4-9.