LG LSRG309ST Service Manual page 42

30” freestanding gas range
Hide thumbs Also See for LSRG309ST:
Table of Contents

Advertisement

WARNING
• Turn off the electrical supply and
gas supply going to the range.
• Replace all panels and parts before
operating.
• RECONNECT all grounding devices.
- Failure to do so can result in severe personal
injury, death or electrical shock.
CAUTION
• Be careful when you work on the
gas range handling the sheet metal
part.
- Sharp edge may be present and you can cut
yourself.
BURNER OUTPUT RATINGS; BTU/HR
Natural Gas, 5" W.C.P
MODEL
BTU RATE
LSRG309ST
BURNER
LF
12,000
LR
9,100
RR
5,000
INNER
RF
19,000
OUTER
CTR
8,000
BROIL
15,500
BAKE
18,000
Orifice Locations for Natural Gas
D
I
C
CONVERSION TO LP GAS
ORIFICE CODE
LSRG309ST
C
D
G
B
A
I
A
B
G
A
B
4) To prevent leakage, make sure the orifice
spuds are securely screwed into the gas
supply tubes.
5) For the extra burner (right front) of
LSRG309ST, three orifice spuds will be
needed.
6) Put the old orifice spuds into conversion kits
and place back on the range for possible
future conversion.
NOTE: If an orifice spud is accidentally
dropped, the cooktop plate can be
raised (see the page 3-4)
5-3