LG LSRG309ST Service Manual page 16

30” freestanding gas range
Hide thumbs Also See for LSRG309ST:
Table of Contents

Advertisement

REMO
REMO
WARNING
• DISCONNECT power supply cord
from the outlet before servicing.
• Replace all panels and parts before
operating.
• RECONNECT all grounding devices.
- Failure to do so can result in severe personal
injury, death or electrical shock.
CAUTION
• Be careful when you work on the gas
range handling the sheet metal part.
- Sharp edge may be present and you can cut
yourself.
1. Turn off the electrical supply and gas supply
going to the range.
2. Pull the range away from the wall so that you can
access the rear panel.
3. Remove two wire covers by removing the screw.
4. Remove the 3 screws from the rear control cover
and remove the cover.
5. Remove the 16 screws from the rear back cover
and remove the cover.
5. Remove the 6 screws of PCB assembly and separate
PCB assembly after unpluging the connectors.
PCB Assembly
COMPONENT ACCESS
VING THE B
A
VING THE B
A
AND KEY P
AND KEY P
Control Cover
Wire cover
Back Cover
CK, CONTR
OL CO
CK, CONTR
OL CO
AD ASSEMBL
AD ASSEMBL
6. Remove the 2 screws of the eyebrow from the
controller sub assembly and remove the eyebrow.
7. Remove the 2 screws of the controller sub assembly.
8. Pull the controller sub assembly and lift it up from the
supporters.
Pull
9. For servicing the key pad PCB, the controller sub
assembly should be separated in whole except the
spark module (IG trans).
3-2
VER
VER
Y
Y
Eyebrow
Lift up

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents