the edge of this flat washer (5), thread the bracket
bolt (1) (with the lock washer (2) and flat washer
(3) already threaded) through the hole in the
bracket (4), through the second flat washer (5),
and then screw the bracket bolt (1) sufficiently
into the bracket post (6) so that the threads fully
grip.
8.
Repeat
Step 7
for the second bracket bolt (1).
9.
Verify that the bracket (4) is connected to the AP
and the wall as illustrated in
Figure 7 AP mounted on wall
1. Bracket post
10. Rotate the AP up or down to the wanted position,
and then firmly tighten both bracket bolts to 50
kgf-cm (43.4 lbf-in).
Figure 7 (page
1
2
3
2. Bracket
3. Wall

Attaching the grounding wire and antennas

1.
Remove the grounding screw shown in
Figure 8 (page 6)
Figure 8 Grounding cable
6).
1. Grounding screw
2.
Attach a grounding cable (2), #10 AWG or
thicker, with the grounding screw.
3.
Tighten the grounding screw and ensure that the
cable is firmly anchored. Ensure that the other
end of the grounding wire is connected to an
earth ground.
4.
Install antennas including antenna connector
lightning arresters as described in the respective
antenna guide available online (search by
antenna part number).
An HP Lightning Arrester (J8996A) Guide is also
available online.