Metrix MX 22 User Manual
Hide thumbs Also See for MX 22:

Advertisement

MX 22
MULTIMETRE NUMERIQUE
4000 points
DIGITAL MULTIMETER
4000 counts
DIGITAL MULTIMETER
4000 Punkte
MULTIMETRO DIGITALE
4000 punti
MULTIMETRO DIGITAL
4000 puntos
Notice de fonctionnement
User's manual
Bedienungsanleitung
Libretto d'istruzioni
Manual de instrucciones

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MX 22 and is the answer not in the manual?

Questions and answers

Summary of Contents for Metrix MX 22

  • Page 1 MX 22 MULTIMETRE NUMERIQUE 4000 points DIGITAL MULTIMETER 4000 counts DIGITAL MULTIMETER 4000 Punkte MULTIMETRO DIGITALE 4000 punti MULTIMETRO DIGITAL 4000 puntos Notice de fonctionnement User's manual Bedienungsanleitung Libretto d'istruzioni Manual de instrucciones...
  • Page 2 MX 22 MULTIMETRE NUMERIQUE 4000 points DIGITAL MULTIMETER 4000 counts DIGITAL-MULTIMETER 4000 Punkte MULTIMETRO DIGITALE 4000 punti MULTIMETRO DIGITAL 4000 puntos User's manual page 14 Copyright © 906129640 - Ed. 7 - 01/13...
  • Page 3 Multimètre digital portable 4000 points...
  • Page 4 LEGENDE Borne d’entrée Mesure de tension V Entrée de référence du multimètre Mesure de tension mV Borne d’entrée : gammes µA/mA Mesure de fréquence Borne d’entrée : gammes A Test de diode et de continuité Mesure de résistance « Ω» Changement de gamme «...
  • Page 5: Table Of Contents

    USER’S MANUAL CONTENTS 1. GENERAL INSTRUCTIONS ............15 1.1 Precautions and safety measures...........15 1.1.1 Preliminary..............15 1.1.2 During use ..............16 1.1.3 Symbols ................16 1.1.4 Instructions ..............16 1.2 Protection mechnisms.............17 1.3 Safety mechanisms..............17 1.4 Warranty..................17 1.5 Maintenance and metrological verification ......17 1.6 Unpacking - Repackaging ............18 1.7 Cleaning ..................18 1.8 Replacing the battery or fuses ..........18 2.
  • Page 6: General Instructions

    1. GENERAL INSTRUCTIONS You are the new owner of a 4000 ct portable digital multimeter and we thank you for your choice. This instrument complies with the specifications set out in the IEC 61010-1, publication concerning safety requirements for electronic measuring apparatus.
  • Page 7: During Use

    1.1.2 During use ∗ Never exceed the protection limit values indicated in the specifications for each type of measurement. ∗ When the multimeter is linked to measurement circuits, do not touch unused terminals. ∗ When the range of the value to be measured is unknown, check that the range initially set on the multimeter is the highest possible or, wherever possible, choose the autoranging mode.
  • Page 8: Protection Mechnisms

    ∗ If any faults or abnormalities are observed, take the instrument out of service and ensure that it cannot be used until it has been checked out. ∗ It is recommended to remove the battery from the instrument if not used.
  • Page 9: Unpacking - Repackaging

    1.6 Unpacking - Repackaging This equipment has been fully checked out mechanically and electrically before shipping. All precautions have been taken to ensure that the instrument arrives at its destination undamaged. However, it is advisable to carry out a rapid check for damage sustained in shipping.
  • Page 10: Description

    2. DESCRIPTION This compact multimeter is a self-contained unit with an appropriate mechanical construction, enables hand-held use. It is designed for a high degree of user safety, maximum protection and unrivalled performance. Display • Liquid crystal display 3 ¾ digits (height of digits : 12 mm) •...
  • Page 11: Terminals (∅ 4 Mm)

    “ MEM ” key : • Fixes the display on the current value and memorises it (short press). • A second short press returns the multimeter to normal mode. • This key is operative in all ranges. “ MIN/MAX ” key : •...
  • Page 12: Function Description

    3. FUNCTION DESCRIPTION AC or DC voltages • Connect the leads to the multimeter (COM and V terminals) and connect it in parallel to the circuit to be tested. • Position the selector switch on the voltmeter function “ V or mV ”. •...
  • Page 13: Resistance Measurement

    Resistance measurement Never test a resistance on a live circuit. • Connect the leads - preferably twisted - to the multimeter (COM and Ω terminals) and to the circuit or the component to be tested. • Position the selector switch on the ohmmeter function “ Ω ”. •...
  • Page 14: General Specifications

    Range 4 kHz 40 kHz 400 kHz 4 MHz 40 MHz Caliber 0.005 - 4kHz 0.03 - 40kHz 0.2 - 400kHz 0.002-0.4MHz 0.02 - 0.4MHz Resolution 1 Hz 10 Hz 0.1 kHz 1 kHz 10 kHz Accuracy 0.1 % R ± 3 D Protection 600 Vrms Sensitivity...
  • Page 16 METRIX Parc des Glaisins 6, avenue du Pré de Challes F - 74940 ANNECY-LE-VIEUX Tél. 33 04 50 64 22 22 - Fax 33 04 50 64 22 00 906129640 - Ed. 7 - 01/13...

Table of Contents