Differential Connections For Ground-Referenced Signal Sources; Figure 4-4. Differential Input Connections For Ground-Referenced Signals - National Instruments VXI-MIO Series User Manual

Multifunction i/o modules for vxibus
Table of Contents

Advertisement

Ground-
Referenced
+
Signal
V
s
Source
-
Common-
Mode
+
Noise and
V
cm
Ground
-
Potential
I/O Connector
National Instruments Corporation
Differential Connections for Ground-Referenced
Signal Sources
Figure 4-4 shows how to connect a ground-referenced signal source to
a channel on a VXI-MIO Series module configured in DIFF input
mode.
ACH<0..7>
ACH<8..15>
Other Input Multiplexers
AISENSE
AIGND
Selected Channel in DIFF Configuration

Figure 4-4. Differential Input Connections for Ground-Referenced Signals

With this type of connection, the PGIA rejects both the common-mode
noise in the signal and the ground potential difference between the
signal source and the VXI-MIO Series module ground, shown as V
in Figure 4-4.
4-15
Chapter 4
Signal Connections
Instrumentation
Amplifier
+
PGIA
+
Measured
-
V
m
Voltage
-
VXI-MIO Series User Manual
cm

Advertisement

Table of Contents