National Instruments NI-488.2 NI-488.2 User Manual page 68

National instruments network hardware - networking hardware user manual
Hide thumbs Also See for NI-488.2 NI-488.2:
Table of Contents

Advertisement

Chapter 7
Interactive Control Utility
Table 7-2. Syntax for Board-Level Traditional NI-488.2 Calls in Interactive Control (Continued)
Syntax
ibnotify mask
ibonl v
ibpad v
ibppc v
ibrd count
ibrda count
ibrdf flname
ibrpp
ibrsc v
ibrsv v
ibsad v
ibsic
ibsre v
ibstop
ibtmo v
ibwait mask
ibwrt wrtbuf
ibwrta wrtbuf
ibwrtf flname
NI-488.2 User Manual
Start an asynchronous wait for selected events where mask is a hex or
decimal integer or a list of mask bit mnemonics (for example,
).
TIMO CMPL
Place device online or offline.
Change primary address.
Parallel poll configure.
Read data where
count
Read data asynchronously where
Read data to file where
Conduct a parallel poll.
Request/release system control.
Request service.
Change secondary address.
Send interface clear.
Set/clear remote enable line.
Abort asynchronous operation.
Change/disable time limit.
Wait for selected event where
of mask bit mnemonics, such as
Write data.
Write data asynchronously.
Write data from a file where
Description
is the bytes to read.
is the bytes to read.
count
is pathname of file to read.
flname
is a hex or decimal integer or a list
mask
ibwait TIMO CMPL
is pathname of file to write.
flname
7-8
ibnotify
.
ni.com

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents