National Instruments MXI Series User Manual page 26

National instruments ni expresscard user manual
Hide thumbs Also See for MXI Series:
Table of Contents

Advertisement

Appendix A
Specifications
Cleaning
NI ExpressCard MXI Series User Manual
Operating Environment
Module ambient temperature range ........0 to 65 °C
Operating relative humidity....................5 to 95%, noncondensing
Storage Environment
Ambient temperature range ....................–20 to 65 °C
Nonoperating thermal shock...................–20 to 65 °C, 5 shocks
Shock and Vibration
Nonoperating shock ................................50 g, 11 ms
Nonoperating vibration,
sinusoidal ................................................15 g 100 to 2000 Hz
Nonoperating drop test ...........................2 drops in 3 mutually exclusive
If you need to clean the module, use a soft, nonmetallic brush. Make sure
that the module is completely dry and free from contaminants before
returning it to service.
(Tested in accordance with
IEC-60068-2-1 and
IEC-60068-2-2.)
(Tested in accordance with
IEC-60068-2-56.)
(Tested in accordance with
IEC-60068-2-1 and
IEC-60068-2-2.)
(Tested in accordance with IEC
60068-2-27.)
(Tested in accordance with IEC
60068-2-6.)
axes from 75 cm onto
no-cushioning vinyl tile surface
A-6
ni.com