National Instruments MXI Series User Manual page 25

National instruments ni expresscard user manual
Hide thumbs Also See for MXI Series:
Table of Contents

Advertisement

NI ExpressCard-8360
Physical
1
Environment
1
Specifications are subject to change without notice.
© National Instruments Corporation
Random Vibration Operating................. 5 to 500 Hz, 0.3 g
Nonoperating .................................. 5 to 500 Hz, 2.4 g
Dimensions............................................. 10.2 × 3.4 cm
Maximum cable length........................... 7 m
Slot requirements ................................... One 34 mm or 54 mm slot
Weight .................................................... 29 g (0.063 lb) typical
Power requirements
Power Rail
+3.3 V
+3.3 V Aux
+1.5 V
Maximum altitude .................................. 2,000 m (at 25 °C ambient
Pollution Degree .................................... 2
Indoor use only
(Tested in accordance with
IEC-60068-2-64. Nonoperating
test profile exceeds the
requirements of
MIL-PRF-28800F, Class 3.)
(4.0 × 1.3 in.)
(ExpressCard)
Typical Current
360 mA
1 mA
0
temperature)
A-5
NI ExpressCard MXI Series User Manual
Appendix A
Specifications
rms
rms
Maximum Current
450 mA
10 mA
0

Advertisement

Table of Contents
loading

Table of Contents