Operating Environment; Storage Environment; Shock And Vibration - National Instruments Module NI PXI-8250 User Manual

National instruments module user's manual
Hide thumbs Also See for Module NI PXI-8250:
Table of Contents

Advertisement

© National Instruments Corporation

Operating Environment

Ambient temperature range.................... 0 to 55 °C
Relative humidity range ......................... 10% to 90%, noncondensing

Storage Environment

Ambient temperature range.................... –40 to 70 °C
Relative humidity range ......................... 5% to 95% noncondensing

Shock and Vibration

Operating shock ..................................... 30 g peak, half-sine, 11 ms pulse
Random vibration
operating................................................. 5 to 500 Hz, 0.3 g
Non-operating ........................................ 5 to 500 Hz, 2.4 g
(Tested in accordance with
IEC-60068-2-1 and
IEC-60068-2-2. Meets
MIL-PRF-28800F Class 3 low
temperature limit and
MIL-PRF-28800F Class 2 high
temperature limit.)
(Tested in accordance with
IEC-60068-2-56.)
(Tested in accordance with
IEC-60068-2-1 and
IEC-60068-2-2. Meets
MIL-PRF-28800F Class 3 limits.)
(Tested in accordance with
IEC-60068-2-56.)
(Tested in accordance with
IEC-60068-2-27. Meets
MIL-PRF-28800F Class 2 limits.)
(Tested in accordance with
IEC-60068-2-64. Nonoperating
test profile exceeds the
requirements of
MIL-PRF-28800F, Class 3.)
A-3
Appendix A
Specifications
rms
rms