P L A N N I N G I N F O R M A T I O N
Before moving the Integrated unit into place, be
sure that the finished opening dimensions, elec-
trical and plumbing locations and minimum door
and drawer clearances are accurate. Refer to the
Installation Specifications illustration for your
model on the following pages. Be sure your
installer has this information before finishing
work is completed.
Integrated models without an automatic ice
I N S T A L L A T I O N
maker will not require the plumbing connections
shown in the illustrations.
Refer to the
installation instruc-
The height of the tall unit is set at 80" (2032).
tions shipped with
You can allow the top of the door panel to
each Sub-Zero
exceed this dimension with caution. If you are
product for detailed
specifications.
working with 84" (2134) or 96" (2438) neighbor-
ing panels, you can utilize door panels to match
this height. Other critical dimensions regarding
the door swing, drawer openings and toe kick
clearance are noted in the Overall Dimensions
illustrations on the following pages. Also refer to
the full-scale illustrations at the end of this
section for specifics on door openings and other
specifications.
IMPORTANT NOTE: The anti-tip bracket must be
installed to prevent the unit from tipping
forward.
E L E C T R I C A L R E Q U I R E M E N T S
A 115 V AC, 60 Hz, 15 amp circuit breaker and
electrical supply are required. A separate circuit,
servicing each base and tall unit, is required.
All Sub-Zero Integrated models are equipped
with a power supply cord with a 3-prong
grounding plug, which must be plugged into a
mating 3-prong grounding-type wall receptacle.
Follow the National Electrical Code and local
codes and ordinances when installing the
receptacle.
IMPORTANT NOTE: The electrical outlet must
be placed so the grounding prong is to the right
of the thinner blades. The outlet must be flush
with the back wall. Refer to the Installation
Specifications illustration for your model for
exact placement.
IMPORTANT NOTE: A ground fault circuit
interrupter (GFCI) is not recommended and may
cause interruption of operation.
Dimensions in parentheses are in
36
millimeters unless otherwise specified.
Do not use an extension cord or 2-prong
adapter. Electrical ground is required.
Do not under any circumstances remove
the power supply cord ground prong.
P L U M B I N G C O N S I D E R A T I O N S
For models with an automatic ice maker, rough
in the water supply line. Connect a
copper line to the house supply, being sure to
use an easily accessible shut-off valve between
the supply and the unit. This shut-off valve
should not be installed behind the unit.
Do not use self-piercing valves. A saddle valve
kit (4200880) is available from your Sub-Zero
dealer. An in-line filter is required when water
conditions have a high sediment content. The ice
maker operates on constant water pressure
between 20 psi (1.4 bar) and 100 psi (6.9 bar).
IMPORTANT NOTE: In some cases, a reverse
osmosis water filter system may not be able to
maintain the minimum pressure consistently.
The Installation Specifications illustration for
your model on the following pages shows the
precise placement of the water line. When
routing the water through the side walls, you
must place the water line within
floor and as close as possible to the back wall.
The line must be routed around the anti-tip
bracket so it clears the bracket and the leveling
feet of the unit as shown in the top view of the
illustration. Regardless of the routing, allow for
27" (686) of excess copper tubing to remain
outside the wall or floor for easy connection to
the unit.
IMPORTANT NOTE: Do not route water supply
line in front of the compressor tray. The tray
must be slid forward for service.
1
/
" OD
4
1
/
" (13) of the
2