Storage Mode; Status Display Mode - Westinghouse WBRC**140F Manual

Gas fired residential combi boiler installation / start-up maintenance / parts warranty
Table of Contents

Advertisement

Figure 39 – CH Set-Point Screen
Factory CH Set-Point is 180
Turn the dial
counterclockwise to lower and clockwise to raise the current CH set-point. After changing the temperature, press the
button to save the setting.
NOTE: The CH Set-Point cannot be changed by pressing the
using an outdoor sensor, the boiler will automatically change the target temperature based on the outdoor reset curve. When using 0-
10V, the boiler will automatically change the target temperature based on input voltage.
NOTE: If input voltage is less than 1.5V the 0-10V will be ignored.
G. STORAGE MODE
Storage Mode indicates that the appliance is heating stored water in the internal storage tank. When Storage Mode is operating the
display appears as follows.
Figure 40 – Storage Mode Screen
H. STATUS DISPLAY MODE
Status Display Mode will activate when the
Figure 41 – Status Mode Screens
Turn the dial
counterclockwise and clockwise to scroll through the displayed parameters. To view parameter details, press the
button at the appropriate screen. Press the
o
o
C). CH Set-Point range is 86 – 180
F (82
button is pressed and held for five seconds when the display panel is powered ON.
or
o
o
F (30 – 82
button if an outdoor sensor or 0-10V is connected to the boiler. When
buttons to leave the parameter.
C).
51
WHL-015 REV. 5.20.16