Changing The Dhw Set-Point; Changing The Temperature Indicator; Changing The Ch Set-Point - Westinghouse WBRC**140F Manual

Gas fired residential combi boiler installation / start-up maintenance / parts warranty
Table of Contents

Advertisement

Installer Mode
D. CHANGING THE DHW SET-POINT
The display shows the
Figure 38 – DHW Set-Point Screens
Press the
button when the display panel is powered ON to change the DHW Set-Point. The DHW icon and current set-point will
display and flash. This indicates that the DHW Set-Point can be changed. Factory DHW Set-Point is 125
o
Point range is 95 – 120
F (35 – 49
Turn the dial
counterclockwise to lower and clockwise to raise the DHW set-point. After changing the temperature, press the
button to save the set-point.
To change the DHW Set-Point above 121
set-point will display. The DHW icon will flash. Then press and hold the
temperature) will display. High temperature DHW Set-Point range is 121 – 140
Turn the dial
counterclockwise to lower and clockwise to raise the DHW set-point. After changing the temperature, press the
button to save the set-point.
Hotter water increases the risk of scald injury. Scalding may occur within 5 seconds at a setting of 140
o
over 125
F can instantly cause severe burns, or death, from scalds. Children, disabled, and elderly are at the highest risk of being
scalded. See instruction manual before setting temperature at appliance. Feel water before bathing or showering!
E. CHANGING THE TEMPERATURE INDICATOR
To change the temperature indicator from Fahrenheit to Celsius, press and hold the
display panel is powered ON. This will toggle the temperature unit indicated on the display.
F. CHANGING THE CH SET-POINT
Press the
button when the display panel is powered ON. The display will appear as follows. The set-point will flash when the CH
Set-Point can be changed.
icon when the DHW set-point can be changed.
o
C).
o
o
F (49.5
C), press the
button when the display panel is powered ON. The current DHW
button for five seconds. The scald warning letter "H" (high
o
o
F (49.5 – 60
C).
button for more than five seconds when the
o
o
F (51
C). Initial DHW Set-
o
o
F (60
C). Water temperature
WHL-015 REV. 5.20.16